Cooling Water Treatment Chemical Solenoid Metering Pump 

  Category : Machinery on-line->Industrial plants->outsole equipment plan

     
Cooling Water Treatment Chemical Solenoid Metering Pump
       

  Product Specification
 
  Model No:      JCMB55-25/2.0
  Country  CN
  Brand  AILIPU
  Packing  Strong carton packing suitable for the long distance transportation.
  Minimum Order  10
  Payment Term  L/C,T/T

 

    Product Detail
  <div id="0m566" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-uj2j7" style="padding:8px 0px 4px 8px;color:#4D6599;font-size:22px;background-color:#C5CCDE;">
Product Description
</div>
</div>
<p style="font-size:13.3333px;">
<b>1. High Speed OperationL:&nbsp;</b><span style="font-size:13.3333px;">Up to 400 strokes per minute</span>
</p>
<p style="font-size:13.3333px;">
<b>2. Compact Size</b>
</p>
<p style="font-size:13.3333px;">
<b>3. Long Lasting Diaphragm:</b><span style="font-size:13.3333px;">&nbsp;The life of the diaphragm is over 5 years, which 5 times as national standard GB/T7782-2008</span>
</p>
<p style="font-size:13.3333px;">
<b>4. Strong Power Supply Compatibility:</b><span style="font-size:13.3333px;">&nbsp;smooth working stability in AC100-240V, and suitable for 50-60Hz range</span>
</p>
<p style="font-size:13.3333px;">
<b>5. High Protection Level</b>
</p>
<p style="font-size:13.3333px;">
<b>6. Double Valve Ball Structure</b>
</p>
<p style="font-size:13.3333px;">
<b><br />
</b>
</p>
<p>
<br />
</p>
<p>
<b>JCMB45 Model</b>
</p>
<p>
<br />
</p>
<div style="vertical-align:top;margin-left:-4px;">
<p>
<table class="MsoNormalTable" border="1" cellspacing="0" cellpadding="0" width="606" style="width:454.35pt;">
<tbody>
<tr>
<td width="105">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Model</span>
</p>
</td>
<td width="76">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Max. Flow</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Max. Pressure</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Pipe Dia. (mm)</span>
</p>
</td>
<td width="123">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Suction Pipe Material</span>
</p>
</td>
<td width="132">
<p class="MsoNormal">
<span style="font-size:8pt;font-family:'';">Discharge Pipe Material</span>
</p>
</td>
</tr>
<tr>
<td width="105">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">JCMB45–3/15</span>
</p>
</td>
<td width="76">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">3.0 L/H</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">15bar</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">In5.5 Out 9.5</span>
</p>
</td>
<td width="123">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PVC</span>
</p>
</td>
<td width="132" valign="top">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PE</span>
</p>
</td>
</tr>
<tr>
<td width="105">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">JCMB45–5/10</span>
</p>
</td>
<td width="76">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">5.0 L/H</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">10bar</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">In5.5 Out 9.5</span>
</p>
</td>
<td width="123">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PVC</span>
</p>
</td>
<td width="132" valign="top">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PE</span>
</p>
</td>
</tr>
<tr>
<td width="105">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">JCMB45–10/5</span>
</p>
</td>
<td width="76">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">10 L/H</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">5bar</span>
</p>
</td>
<td width="85">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">In5.5 Out 9.5</span>
</p>
</td>
<td width="123">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PVC</span>
</p>
</td>
<td width="132" valign="top">
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PE</span><b>&nbsp;</b>
</p>
</td>
</tr>
</tbody>
</table>
</p>
<p>
<br />
</p>
<p>
<b>JCMB55 Model</b>
</p>
<table class="MsoNormalTable" border="1" cellspacing="0" cellpadding="0" width="630" style="width:472.5pt;">
<tbody>
<tr>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Model</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Max. Flow</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Max. Pressure</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Pipe Dia. (mm)</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Suction Pipe Material</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">Discharge Pipe Material</span>
</p>
</td>
</tr>
<tr>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">JCMB55–15/3.2</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">15 L/H</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">3.2bar</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">In6.5 Out 9.5</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PVC</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PE</span>
</p>
</td>
</tr>
<tr>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">JCMB55–20/2.5</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">20 L/H</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">2.5bar</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">In6.5 Out 9.5</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PVC</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PE</span>
</p>
</td>
</tr>
<tr>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">JCMB55–25/2.0</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">25 L/H</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">2.0bar</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">In6.5 Out 9.5</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PVC</span>
</p>
</td>
<td>
<p class="MsoNormal" align="left">
<span style="font-size:8pt;font-family:'';">PE</span>
</p>
</td>
</tr>
</tbody>
</table>
<p class="MsoNormal">
&nbsp;
</p>
<p>
<br />
</p>
<p>
<br />
</p>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="kpsek" style="vertical-align:top;">
<img src="http://i.bosscdn.com/uploads/12/54/cf/f1396c2fa3c03b2d0ad691c552.png" width="334" height="319" title="Solenoid pump outline dimention" alt="Solenoid pump outline dimention" /><img src="http://i.bosscdn.com/uploads/2e/08/3d/dfe342c4fc8412a9cde27828f4.png" width="371" height="340" title="Solenoid pump " alt="Solenoid pump " />
</div>
</div>
<p>
<br />
</p>
<div style="font-size:13.3333px;vertical-align:top;">
<div id="kmoa3" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-k4anm" style="padding:8px 0px 4px 8px;color:#4D6599;font-size:22px;background-color:#C5CCDE;">
JCMB Series
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="4tie7" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/b0/ab/13/329d8641bbdb9fd10530ef94e8.png" width="218" height="213" title="Solenoid metering pump manual control" alt="Solenoid metering pump manual control" />
</div>
<div style="vertical-align:top;">
<div id="0wlnb" style="vertical-align:top;">
<h3 style="font-size:16px;color:#333333;">
JCMB-S
</h3>
</div>
<div id="femn0" style="vertical-align:top;">
<p>
1. Manual &nbsp;flow&nbsp;adjusting&nbsp;
</p>
<p>
2. Pump On/Off indicator
</p>
<p>
3. Displayable frequency percentage
</p>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="emv3o" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/ad/84/28/d5a06bcffafeacad193b2a0c1b.png" width="198" height="210" title="Solenoid metering pump Auto-Adjust (Digital impulse signal control)" alt="Solenoid metering pump Auto-Adjust (Digital impulse signal control)" />
</div>
<div style="vertical-align:top;">
<div id="qri9x" style="vertical-align:top;">
<h3 style="font-size:16px;color:#333333;">
JCMB-C Auto-Adjust (Digital impulse signal control)
</h3>
</div>
<div id="b8b7t" style="vertical-align:top;">
<p>
<span style="line-height:1.5;"></span>
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
Two control modes available:
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
1. Manual
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
2. Auto: controlled by the signal received&nbsp;<span style="line-height:1.5;">&nbsp;(Digital pulse signal)&nbsp;</span>
</p>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="sb56z" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/f6/e4/43/4a67b2e29d7cc9ea21da0e8390.png" width="198" height="213" title="Solenoid metering pump Auto-Adjust (4-20mA electric current signal control with Rs485 communication interface)" alt="Solenoid metering pump Auto-Adjust (4-20mA electric current signal control with Rs485 communication interface)" />
</div>
<div style="vertical-align:top;">
<div id="4wpaw" style="vertical-align:top;">
<h3 style="font-size:16px;color:#333333;">
JCMB-H Auto-Adjust (4-20mA electric current signal control)
</h3>
</div>
<div id="dl8sl" style="vertical-align:top;">
<p class="MsoNormal" align="left" style="vertical-align:top;">
Two control modes available:
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
1. Manual
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
2. Auto: controlled by the signal received&nbsp;<span style="line-height:1.5;">&nbsp;(4-20mA electric current signal)&nbsp;</span>
</p>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="7qkbu" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/ca/84/f1/6c6de1b00ab4e61c2f98dcb72d.png" width="198" height="223" title="Solenoid metering pump Auto-Adjust (Digital impulse signal control feedback)" alt="Solenoid metering pump Auto-Adjust (Digital impulse signal control feedback)" />
</div>
<div style="vertical-align:top;">
<div id="iwxjz" style="vertical-align:top;">
<h3 style="font-size:16px;color:#333333;">
JCMB-F Auto-Adjust (Digital impulse signal control feedback)
</h3>
</div>
<div id="4kve8" style="vertical-align:top;">
<p class="MsoNormal" align="left" style="vertical-align:top;">
Two control modes available:
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
1. Manual
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
2. Auto: controlled by the signal received&nbsp;<span style="line-height:1.5;">(Digital pulse signal ) and feedback operating signal for remote control.</span>
</p>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="fnd6t" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/ca/84/f1/6c6de1b00ab4e61c2f98dcb72d.png" width="198" height="227" title="Solenoid metering pump Auto-Adjust (Digital impulse signal control feedback with Rs485 communication interface)" alt="Solenoid metering pump Auto-Adjust (Digital impulse signal control feedback with Rs485 communication interface)" />
</div>
<div style="vertical-align:top;">
<div id="r5xdx" style="vertical-align:top;">
<h3 style="font-size:16px;color:#333333;">
JCMB-CR Auto-Adjust (Digital impulse signal control feedback with Rs485 communication interface)
</h3>
</div>
<div id="vniw8" style="vertical-align:top;">
<p class="MsoNormal" align="left" style="vertical-align:top;">
Two control modes available:
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
1. Manual
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
2. Auto: controlled by the signal received&nbsp;<span style="line-height:1.5;">(Digital pulse signal ) and feedback operating signal for remote control&nbsp;</span><span style="line-height:1.5;">with Rs485 communication interface by MODBUS protocol.&nbsp;</span>
</p>
</div>
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="wqhfh" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/f6/e4/43/4a67b2e29d7cc9ea21da0e8390.png" width="198" height="239" title="Solenoid metering pump Auto-Adjust (4-20mA electric current signal control with Rs485 communication interface)" alt="Solenoid metering pump Auto-Adjust (4-20mA electric current signal control with Rs485 communication interface)" />
</div>
<div style="vertical-align:top;">
<div id="3q6rp" style="vertical-align:top;">
<h3 style="font-size:16px;color:#333333;">
JCMB-H Auto-Adjust (4-20mA electric current signal control with Rs485 communication interface)
</h3>
</div>
<div id="wtypr" style="vertical-align:top;">
<p class="MsoNormal" align="left" style="vertical-align:top;">
Two control modes available:
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
1. Manual
</p>
<p class="MsoNormal" align="left" style="vertical-align:top;">
2. Auto: controlled by the signal received (4-20mA electric current signal) with Rs485 communication interface: using MODBUS protocol.&nbsp;
</p>
</div>
</div>
</div>
</div>
<div style="font-size:13.3333px;vertical-align:top;">
<div id="3xpeo" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-nrm29" style="padding:8px 0px 4px 8px;color:#4D6599;font-size:22px;background-color:#C5CCDE;">
Our Certifications
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="gjkj5" style="vertical-align:top;">
<img src="http://i.bosscdn.com/product/87/a4/cd/c38cdfb091fd015823217cce1d.jpg" width="146" height="207" title="ISO14001" alt="ISO14001" /><img src="http://i.bosscdn.com/product/51/8f/2b/c7315ca00623eaef75d1a2c084.jpg" width="148" height="208" title="ISO9001" alt="ISO9001" /><img src="http://i.bosscdn.com/product/36/c6/51/7f000be59064c20313593419fe.jpg" width="148" height="207" title="CE1" alt="CE1" /><img src="http://i.bosscdn.com/product/0a/90/af/83c57b8593eb3b7e52e84784ae.jpg" width="146" height="207" title="CE2" alt="CE2" />
</div>
</div>
</div>alipu.com

  More Products from this Supplier
 
Water Treatment Chlorine Solenoid Metering Pump

Water Treatment Chlorine Solenoid Metering Pump
Diaphragm Metering Pump for chemical dosing

Diaphragm Metering Pump for chemical dosing
Water Treatment Micro flowrate Dosing Pump

Water Treatment Micro flowrate Dosing Pump
Swimming Pool Chemical Solenoid Dosing Pump

Swimming Pool Chemical Solenoid Dosing Pump
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .