Sign In Join Help
 
Zhejiang Ailipu Technology Co., LTD.

 
 
Recommended Results 
 
Phosphate Injection Diaphragm Dosing Pump 

  Category : Machinery on-line->Industrial plants->outsole equipment plan

     
Phosphate Injection Diaphragm Dosing Pump
       

  Product Specification
 
  Model No:      JXM-A-22/1.2
  Country  CN
  Brand  AILIPU
  Packing  Strong carton suitable for international transportationG.W.:20KG/Set
  Minimum Order  5
  Payment Term  L/C,T/T

 

    Product Detail
  <div>
</div>
<div>
<div style="vertical-align:top;">
<div id="d3fjl" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-5wi47" style="padding:8px 0 4px 8px;color:#4D6599;background-color:#C5CCDE;font-size:22px;">
Product Description
</div>
</div>
<div style="vertical-align:top;margin-left:-4px;">
<div id="o4x3c">
<p>
&nbsp;After finishing the above mentioned checks, users can start the metering pump and also should observe&nbsp;and listen attentively to the pump.
</p>
<p class="MsoNormal">
Users can loosen the stroke set screw on the adjusting carrier so as to control the flow rate by adjusting the 0.001mm interval scale. As for the JXM-A type pumps, to true&nbsp;clockwise is to increase the flow rate, while for the JZM-A type pumps, to turn clockwise is to decrease the flow rate. All the stroke adjusting scopes are marked in percentage and the minimum interval on the handle is 1%. For adjusting the handle to reach a suitable flow rate, users should tighten up the set screw so as to maintain the flow rate.
</p>
<p>
<br />
</p>
</div>
</div>
<div>
<div id="f50k8">
<div style="font-family:&quot;vertical-align:top;margin-left:-4px;">
<div id="rdai1">
<div>
<div id="rdai1">
<table class="MsoNormalTable" style="font-family:&quot;width:538pt;">
<tbody>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
<br />
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="right">
l/h
</p>
</td>
<td width="103" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="right">
&nbsp;&nbsp;(Mpa)
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
&nbsp;
</p>
</td>
<td width="79" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="right">
(mm)
</p>
</td>
<td width="99" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="right">
(mm)
</p>
</td>
<td width="88" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="right">
(KW)
</p>
</td>
<td width="67" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="right">
(KG)
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 2.25/1.2
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
2.25
</p>
</td>
<td width="103" valign="center" rowspan="5" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
1.2
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
36
</p>
</td>
<td width="79" valign="center" rowspan="3" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
1.2
</p>
</td>
<td width="99" valign="center" rowspan="3" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
DN8
</p>
</td>
<td width="88" valign="center" rowspan="9" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
0.37KW
</p>
</td>
<td width="67" valign="center" rowspan="12" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
18
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 4.5/1.2
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
4.5
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
&nbsp;
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 9/1.2
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
9
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
144
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 22/1.2
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
22
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
72
</p>
</td>
<td width="79" valign="center" rowspan="2" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
4
</p>
</td>
<td width="99" valign="center" rowspan="5" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
DN15
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 44/1.2
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
44
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
144
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 85/1.0
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
85
</p>
</td>
<td width="103" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
1
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
72
</p>
</td>
<td width="79" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
6
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 120/0.7
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
120
</p>
</td>
<td width="103" valign="center" rowspan="3" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
0.7
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
72
</p>
</td>
<td width="79" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
8
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 170/0.7
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
170
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
144
</p>
</td>
<td width="79" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
6
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 240/0.7
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
240
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
144
</p>
</td>
<td width="79" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
8
</p>
</td>
<td width="99" valign="center" rowspan="4" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
DN25
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 315/0.5
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
315
</p>
</td>
<td width="103" valign="center" rowspan="3" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
0.5
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
144
</p>
</td>
<td width="79" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
8
</p>
</td>
<td width="88" valign="center" rowspan="3" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
0.55KW
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 400/0.5
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
400
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
144
</p>
</td>
<td width="79" valign="center" rowspan="2" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
10
</p>
</td>
</tr>
<tr>
<td width="111" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
JXM-A 500/0.5
</p>
</td>
<td width="96" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
500
</p>
</td>
<td width="70" valign="center" style="border:1pt solid #000000;">
<p class="MsoNormal" align="center">
180
</p>
</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
</div>
</div>
</div>
<div>
<p>
<br />
</p>
<p>
<img src="http://i.bosscdn.com/product/05/01/d4/5fcc0b285939b426aeba8e51a1.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=25&p=9&t=80&text=emphaWxpcHUuYm9zc2dvby5jb20%3D" width="750" height="416" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" />
</p>
<p>
<br />
</p>
<div id="f5fer" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-0mb6c" style="padding:8px 0px 4px 8px;color:#4D6599;background-color:#C5CCDE;font-size:22px;">
Products Show
</div>
</div>
<p>
<br />
</p>
<p>
<br />
</p>
</div>
</div>
<div>
<div id="eo1lz">
<div id="ali-anchor-AliMaya-comt4">
</div>
</div>
<div>
<div id="91l29">
<div>
<img src="http://i.bosscdn.com/uploads/ed/e9/b9/ab46793ce69e8a25d25ffccaf3.jpg" width="750" height="444" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" />
</div>
</div>
</div>
<div>
<div id="jhnu2">
<img src="http://i.bosscdn.com/product/68/57/47/3704401139a0aa0c8b8af88350.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=25&p=9&t=80&text=emphaWxpcHUuYm9zc2dvby5jb20%3D" width="750" height="500" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" /><br />
</div>
</div>
<div>
<div>
<div id="hepim">
<h3>
Technical Specifications
</h3>
</div>
<div id="ukd6q">
<p>
* Flow rates up to 500L/H, pressure up to 12Bar<br />
* Adjustment of flowrate from 0% - 100% while running or stopped<br />
* Accuracy +/- 2% of 100% rated flow<br />
* Mechanically actuated PTFE diaphragm<br />
* Maximum temperature of pumped fluid: +10℃ - 40℃<br />
* Maximum suction up to 2M
</p>
</div>
</div>
</div>
<div>
<div>
<div id="esde4">
<h3>
Features &amp; Benefits
</h3>
</div>
<div id="cslyb">
<p>
* Mechanical actuated diagragm design, easy operation and with the convenience maintanence<br />
* Changeable eccentric drive, no leakage with security delivery<br />
* Rugged construction designed to withstand tough environments<br />
* Oil bath lubrication for all of drive components<br />
* Various pump head material (PVC, PVDF, SS304, SS316 etc.) to meet different solution needs<br />
* Available with the manual control and digital control model&nbsp;
</p>
</div>
</div>
</div>
<div>
<div>
<div id="43wbm">
<h3>
Control
</h3>
</div>
<div id="extp9">
<p>
* Manual stroke adjustment<br />
* Stroke actuator with 4-20mA signal<br />
* Digital controller with 4-20mA signal&nbsp;
</p>
</div>
</div>
</div>
</div>
<div>
<div id="32g4k">
<div id="ali-anchor-AliMaya-qxafv">
Our Team
</div>
</div>
<div>
<div>
<div id="9hf3h">
<div>
<img src="http://i.bosscdn.com/uploads/b4/8f/23/61e4d04422fe67e0071059bc15.jpg" width="325" height="216" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" /><img src="http://i.bosscdn.com/uploads/ec/ad/f3/5289e48655961d38cb13244dbe.jpg" width="325" height="216" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" />
</div>
</div>
</div>
</div>
</div>
<div>
<div id="xgr65">
<div id="ali-anchor-AliMaya-mpowd">
<div id="31eqw" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-m17fh" style="padding:8px 0px 4px 8px;color:#4D6599;background-color:#C5CCDE;font-size:22px;">
Our Company
</div>
</div>
</div>
</div>
<div>
<div>
<div>
<div id="jxj2e">
<div>
<img src="http://i.bosscdn.com/uploads/bd/88/da/b2a030b5d4aabc778c1e948ce4.jpg" width="371" height="278" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" /><img src="http://i.bosscdn.com/uploads/f7/f5/a8/cbbc2cfe5314e68f6f6dc66786.jpg" width="371" height="278" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" />
</div>
</div>
</div>
</div>
</div>
<div>
<div id="17bfj">
<div>
<img src="http://i.bosscdn.com/uploads/9b/4a/67/1c8b5e6736e9819898a8109b57.jpg" width="750" height="515" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" />
</div>
</div>
</div>
</div>
<div>
<div id="pgksb">
<div id="ali-anchor-AliMaya-p86bu">
<div id="r3v7y" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-10s6p" style="padding:8px 0px 4px 8px;color:#4D6599;background-color:#C5CCDE;font-size:22px;">
Our Certifications
</div>
</div>
</div>
</div>
<div>
<div id="cxfzs">
<div>
<img src="http://i.bosscdn.com/uploads/f9/21/56/8a1e04f95bcaefe55ac08e1317.jpg" width="148" height="211" title="Diaphragm Chemical Metering Pump" alt="Diaphragm Chemical Metering Pump" /><img src="http://i.bosscdn.com/uploads/bb/80/66/4361fdb18a55d2409b5eb16358.jpg" width="148" height="203" title="Diaphragm Chemical Metering Pump" alt="Diaphragm Chemical Metering Pump" /><img src="http://i.bosscdn.com/uploads/1c/6e/bd/b70b171b4025476974ff8d81b1.jpg" width="164" height="232" title="Diaphragm Chemical Metering Pump" alt="Diaphragm Chemical Metering Pump" /><img src="http://i.bosscdn.com/uploads/8e/fc/a7/f2cf9e9b0e0f9ef929eaa9bf1f.jpg" width="164" height="231" title="Diaphragm Chemical Metering Pump" alt="Diaphragm Chemical Metering Pump" />
</div>
</div>
</div>
</div>
<div>
<div id="sp1gv">
<div id="ali-anchor-AliMaya-lklxi">
<div id="elz0r" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-vts0f" style="padding:8px 0px 4px 8px;color:#4D6599;background-color:#C5CCDE;font-size:22px;">
Customer Photo
</div>
</div>
</div>
</div>
<div>
<div id="pdtab">
<div>
<img src="http://i.bosscdn.com/uploads/62/28/ae/8a664457e96bbf8002d36d3fb0.jpg" width="480" height="320" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" /><img src="http://i.bosscdn.com/uploads/49/a2/8a/adf9bdef79c5eb9220b3dba766.jpg" width="480" height="320" title="Digital Control Metering Pump" alt="Digital Control Metering Pump" />
</div>
</div>
</div>
</div>
<div>
<div id="jg035">
<div id="ali-anchor-AliMaya-9set5">
<div id="5m3tw" style="vertical-align:top;">
<div id="ali-anchor-AliMaya-y9jay" style="padding:8px 0px 4px 8px;color:#4D6599;background-color:#C5CCDE;font-size:22px;">
FAQ
</div>
</div>
</div>
</div>
<div>
<div>
<div id="ehbd5">
<h3>
Q: Are you trading company or manufacturer ?
</h3>
</div>
<div id="haukz">
<p>
A: We are factory, and our factory has the independent research and development capacity
</p>
</div>
</div>
</div>
<div>
<div>
<div id="5vg0c">
<h3>
Q: How long is your delivery time?
</h3>
</div>
<div id="o73di">
<p>
A: Generally it is 3 days if the goods are in stock. or it is 15-20 days if the goods are not in stock, it is according to quantity.
</p>
</div>
</div>
</div>
<div>
<div>
<div id="mm0mz">
<h3>
Q: Do you provide samples ? is it free or extra ?
</h3>
</div>
<div id="s7cx6">
<p>
A: Yes, we could offer sample but it must be paid
</p>
</div>
</div>
</div>
<div>
<div>
<div id="q66y3">
<h3>
Q: What is your terms of payment ?
</h3>
</div>
<div id="u9i6u">
<p>
A:&nbsp;TT, LC. etc.....
</p>
</div>
</div>
</div>
</div>
</div>
<div>
</div>alipu.com

  More Products from this Supplier
 
Water Plant Diaphragm Metering Pump

Water Plant Diaphragm Metering Pump
Swimming Pool Chlorine Solenoid Dosing Pump

Swimming Pool Chlorine Solenoid Dosing Pump
Diaphragm Metering Pump for chemical dosing

Diaphragm Metering Pump for chemical dosing
Electric Mechanical Diaphragm Metering Pump

Electric Mechanical Diaphragm Metering Pump
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .