Sign In Join Help
 
Wenzhou Korlen Electric Appliances Co., Ltd.

 
 
Recommended Results 
 
Supply 100A 240-415V Residual Current Circuit Breakers 

  Category : Electronic and electrical->Electronic Parts->wiring equipments

     
Supply 100A 240-415V Residual Current Circuit Breakers
       

  Product Specification
 
  Model No:      KNL1-100
  Country  CN
  Brand  Korlen
  Packing  carton
  Minimum Order  100
  Payment Term  L/C,T/T,D/P,Paypal,Money Gram,Western Union

 

    Product Detail
  <p class="MsoNormal">
<span style="line-height:1.5;">KNL1 series Residual current circuit breaker(without over-current protection) is suitable for the line of AC 50/60Hz, voltage 240V(2&nbsp;pole)/415V(4&nbsp;pole), rated current up to&nbsp;100A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power rapidly to protect human safety and prevent the accident due to the current leakage. It can be used as infrequent changeover of the line in normal situation.It is applicable to industrial site, commercial site, tall building and civil house.</span>
</p>
<p class="MsoNormal">
<br />
</p>
<p class="MsoNormal">
&nbsp; &nbsp; It complies with standard of GB16916.1&nbsp;and IEC/EN61008.1.
</p>
Each phase of conductor at the circuit breaker passes through the zero-sequence current transformer, and the secondary side of coil connects with the electromagnetic tripper.Under normal condition, the vector sum of each phase of current passing through zero-sequence current transformer is zero.The flux of the zero-sequence current transformer is zero.And the secondary output voltage is zero and the circuit breaker doesn't zero, and the zero-sequence current transformer would produce the magnetic flux, and the secondary side of coil would output the voltage.Once the leak current increases to drive the output voltage at the secondary side to grow to certain level, the electromagnetic release would activate to drive the operation mechanism to act to break the contact that connects the power, finally to realize the leak protection.
<p>
<br />
</p>
<p class="MsoNormal">
<table class="tcs" width="615" height="304" bordercolor="#000000" border="1">
<tbody>
<tr>
<td class="tcs-selected">
Frame class
</td>
<td class="tcs-selected">
100A
</td>
</tr>
<tr>
<td class="tcs-selected">
Rated working voltage
</td>
<td class="tcs-selected">
240/415V
</td>
</tr>
<tr>
<td class="tcs-selected">
Rated frequency
</td>
<td class="tcs-selected">
50/60Hz
</td>
</tr>
<tr>
<td class="tcs-selected">
Rated working current
</td>
<td class="tcs-selected">
63,80,100A
</td>
</tr>
<tr>
<td class="tcs-selected">
Rated residual operating current
</td>
<td class="tcs-selected">
0.03,0.1,0.3,0.5A
</td>
</tr>
<tr>
<td class="tcs-selected">
Rated residual un-operating current
</td>
<td class="tcs-selected">
0.015,0.05,0.15,0.25A
</td>
</tr>
<tr>
<td class="tcs-selected">
Sensibility
</td>
<td class="tcs-selected">
AC Type
</td>
</tr>
<tr>
<td class="tcs-selected">
Maximum operating time
</td>
<td class="tcs-selected">
IΔn t≤0.1s , 5IΔn t≤0.04
</td>
</tr>
<tr>
<td class="tcs-selected">
Rated making and breaking capacity
</td>
<td class="tcs-selected">
1500A
</td>
</tr>
<tr>
<td class="tcs-selected">
Limiting value of un-operating current
</td>
<td class="tcs-selected">
6In
</td>
</tr>
<tr>
<td class="tcs-selected">
Rated limiting short-circuit current
</td>
<td class="tcs-selected">
3000A
</td>
</tr>
<tr>
<td class="tcs-selected">
Pole number
</td>
<td class="tcs-selected">
2,4P
</td>
</tr>
<tr>
<td class="tcs-selected">
Mechanical life
</td>
<td class="tcs-selected">
10000
</td>
</tr>
<tr>
<td class="tcs-selected">
Electric life
</td>
<td class="tcs-selected">
4000
</td>
</tr>
</tbody>
</table>
</p>
<p class="MsoNormal">
<br />
</p>
<p class="MsoNormal">
<img src="http://i.bosscdn.com/product/6e/35/18/675ec92aed8ee1ea6c0f539df0.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=9&t=80&text=a29ybGVuNjc2Ni5ib3NzZ29vLmNvbQ%3D%3D" title="Supply 100A Swich" alt="Supply 100A Swich" width="888" height="435" /><img src="http://i.bosscdn.com/product/27/e6/a4/b76e08684de23f1d55075cc631.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=9&t=80&text=a29ybGVuNjc2Ni5ib3NzZ29vLmNvbQ%3D%3D" title="Supply 100A Swich" alt="Supply 100A Swich" width="880" height="660" /><img src="http://i.bosscdn.com/product/e3/43/32/9f711d6c6650a115e557f4b53b.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=9&t=80&text=a29ybGVuNjc2Ni5ib3NzZ29vLmNvbQ%3D%3D" title="Supply 100A Swich" alt="Supply 100A Swich" width="880" height="1173" /><img src="http://i.bosscdn.com/product/1a/f5/eb/892ada0702e02b0be5cf22cccc.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=9&t=80&text=a29ybGVuNjc2Ni5ib3NzZ29vLmNvbQ%3D%3D" title="Residual Current Swich" alt="Residual Current Swich" width="880" height="1173" /><img src="http://i.bosscdn.com/product/9e/a4/d0/a074f2d20895714d44f4302d7a.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=9&t=80&text=a29ybGVuNjc2Ni5ib3NzZ29vLmNvbQ%3D%3D" title="Residual Current Swich" alt="Residual Current Swich" width="880" height="880" />
</p>
<p>
<img src="http://i.bosscdn.com/product/cd/77/d6/42a76e1e995be50f0d7e77c685.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=9&t=80&text=a29ybGVuNjc2Ni5ib3NzZ29vLmNvbQ%3D%3D" title="Residual Current Swich" alt="Residual Current Swich" width="880" height="600" />
</p>korlenelectric.com

  More Products from this Supplier
 
House Circuit Breakers Without Over-Current Protection

House Circuit Breakers Without Over-Current Protection
High quality new type Mini Circuit Breakers

High quality new type Mini Circuit Breakers
High Breaking Mini Circuit Breakers

High Breaking Mini Circuit Breakers
Low Voltage Miniature Circuit Breaker 415V Normal Type

Low Voltage Miniature Circuit Breaker 415V Normal Type
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .