1600A Molded Case Circuit breaker 

  Category : Electronic and electrical->Electronic Parts->wiring equipments

     
1600A Molded Case Circuit breaker
       

  Product Specification
 
  Model No:      KNM3
  Country  CN
  Brand  Korlen
  Packing  carton
  Minimum Order  100
  Payment Term  L/C,T/T,D/P,Paypal,Money Gram,Western Union

 

    Product Detail
  <p class="MsoNormal">
<span style="font-family:arial;line-height:normal;"> </span>
</p>
<p class="MsoNormal" align="justify">
KNM3 Series moulded-case circuit-breakers guarantee an extremely&nbsp;high performance level while being progressively smaller in&nbsp;size, simple to install and able to provide increasingly better&nbsp;safety guarantees for the operator.<br />
KNM3 Series&nbsp;Moulded-case circuit-breakers can be used in low voltage&nbsp;civil and industrial installations with 1 to 3200 A operating&nbsp;current.<br />
Since assembly instructions are simple, trip units can quickly&nbsp;and easily be replaced;&nbsp;even in the field.<br />
All this makes the circuit-breakers very easy to operate with&nbsp;considerable savings due to rationalized stock management.
</p>
<!--EndFragment-->
<p>
<br />
</p>
<p class="MsoNormal">
This product complies with standard IEC60947-2, GB14048.2
</p>
<p>
<table class="tcs ke-zeroborder">
<tbody>
<tr>
<td class="tcs-selected">
NO.
</td>
<td class="tcs-selected">
testing current name<br />
</td>
<td class="tcs-selected">
I/In
</td>
<td class="tcs-selected">
Assumed time
</td>
<td class="tcs-selected">
Starting<br />
situation
</td>
</tr>
<tr>
<td class="tcs-selected">
1
</td>
<td class="tcs-selected">
Assumed un-<br />
tripping current
</td>
<td class="tcs-selected">
1.05
</td>
<td class="tcs-selected">
2h(In&gt;63A),<br />
1h(In≤63A)
</td>
<td class="tcs-selected">
Cold state
</td>
</tr>
<tr>
<td class="tcs-selected">
2
</td>
<td class="tcs-selected">
Assumed tripping<br />
current
</td>
<td class="tcs-selected">
1.30
</td>
<td class="tcs-selected">
2h(In&gt;63A),<br />
1h(In≤63A)
</td>
<td class="tcs-selected">
Start right&nbsp;
</td>
</tr>
</tbody>
</table>
<table class="tcs ke-zeroborder">
<tbody>
<tr>
<td colspan="2" class="tcs-selected">
Type
</td>
<td class="tcs-selected">
KNM3-125N
</td>
<td class="tcs-selected">
KNM3-160N
</td>
<td class="tcs-selected">
KNM3-250N
</td>
<td class="tcs-selected">
KNM3-400N
</td>
<td class="tcs-selected">
KNM3-630N
</td>
<td class="tcs-selected">
KNM3-800N
</td>
</tr>
<tr>
<td colspan="2" class="tcs-selected">
Rated current In(A)
</td>
<td class="tcs-selected">
125A
</td>
<td class="tcs-selected">
160A
</td>
<td class="tcs-selected">
250A
</td>
<td class="tcs-selected">
400A
</td>
<td class="tcs-selected">
630A
</td>
<td class="tcs-selected">
800A
</td>
</tr>
<tr>
<td colspan="2" class="tcs-selected">
Rated insulation voltage(V)
</td>
<td class="tcs-selected">
500
</td>
<td class="tcs-selected">
690
</td>
<td class="tcs-selected">
800
</td>
<td class="tcs-selected">
800
</td>
<td class="tcs-selected">
800
</td>
<td class="tcs-selected">
800
</td>
</tr>
<tr>
<td colspan="2" class="tcs-selected">
Rated pulse voltage(KV)
</td>
<td class="tcs-selected">
6
</td>
<td class="tcs-selected">
6
</td>
<td class="tcs-selected">
8
</td>
<td class="tcs-selected">
8
</td>
<td class="tcs-selected">
8
</td>
<td class="tcs-selected">
8
</td>
</tr>
<tr>
<td colspan="2" rowspan="2" class="tcs-selected">
Rated working voltage ue (V)
</td>
<td class="tcs-selected">
AC500
</td>
<td class="tcs-selected">
AC690
</td>
<td class="tcs-selected">
AC690
</td>
<td class="tcs-selected">
AC690
</td>
<td class="tcs-selected">
AC690
</td>
<td class="tcs-selected">
AC690
</td>
</tr>
<tr>
<td class="tcs-selected">
DC250
</td>
<td class="tcs-selected">
DC500
</td>
<td class="tcs-selected">
DC750
</td>
<td class="tcs-selected">
DC750
</td>
<td class="tcs-selected">
DC750
</td>
<td class="tcs-selected">
DC750
</td>
</tr>
<tr>
<td rowspan="5" class="tcs-selected">
Ultimate<br />
short-circuit<br />
breaking<br />
capacity<br />
lcu(KA)<br />
AC 50/60Hz
</td>
<td class="tcs-selected">
220/240V
</td>
<td class="tcs-selected">
40
</td>
<td class="tcs-selected">
50
</td>
<td class="tcs-selected">
65
</td>
<td class="tcs-selected">
65
</td>
<td class="tcs-selected">
65
</td>
<td class="tcs-selected">
65
</td>
</tr>
<tr>
<td class="tcs-selected">
380/415V
</td>
<td class="tcs-selected">
25
</td>
<td class="tcs-selected">
35
</td>
<td class="tcs-selected">
35
</td>
<td class="tcs-selected">
35
</td>
<td class="tcs-selected">
35
</td>
<td class="tcs-selected">
35
</td>
</tr>
<tr>
<td class="tcs-selected">
440V
</td>
<td class="tcs-selected">
16
</td>
<td class="tcs-selected">
20
</td>
<td class="tcs-selected">
30
</td>
<td class="tcs-selected">
30
</td>
<td class="tcs-selected">
30
</td>
<td class="tcs-selected">
30
</td>
</tr>
<tr>
<td class="tcs-selected">
500V
</td>
<td class="tcs-selected">
12
</td>
<td class="tcs-selected">
12
</td>
<td class="tcs-selected">
25
</td>
<td class="tcs-selected">
25
</td>
<td class="tcs-selected">
25
</td>
<td class="tcs-selected">
25
</td>
</tr>
<tr>
<td class="tcs-selected">
690V
</td>
<td class="tcs-selected">
-
</td>
<td class="tcs-selected">
8
</td>
<td class="tcs-selected">
14
</td>
<td class="tcs-selected">
20
</td>
<td class="tcs-selected">
20
</td>
<td class="tcs-selected">
20
</td>
</tr>
<tr>
<td colspan="2" class="tcs-selected">
Operative short-circuit Breaking capacity
</td>
<td class="tcs-selected">
.
</td>
<td class="tcs-selected">
.
</td>
<td class="tcs-selected">
.
</td>
<td class="tcs-selected">
.
</td>
<td class="tcs-selected">
.
</td>
<td class="tcs-selected">
.
</td>
</tr>
<tr>
<td colspan="2" class="tcs-selected">
Isolation function
</td>
<td class="tcs-selected">
A
</td>
<td class="tcs-selected">
A
</td>
<td class="tcs-selected">
A
</td>
<td class="tcs-selected">
A
</td>
<td class="tcs-selected">
B
</td>
<td class="tcs-selected">
B
</td>
</tr>
<tr>
<td colspan="2" class="tcs-selected">
Usage category
</td>
<td class="tcs-selected">
.
</td>
<td class="tcs-selected">
.
</td>
<td class="tcs-selected">
<br />
</td>
<td class="tcs-selected">
<br />
</td>
<td class="tcs-selected">
<br />
</td>
<td class="tcs-selected">
<br />
</td>
</tr>
<tr>
<td rowspan="3" class="tcs-selected">
Mode<br />
of<br />
tripping<br />
unit
</td>
<td class="tcs-selected">
Unadjustable
</td>
<td class="tcs-selected">
<br />
</td>
<td class="tcs-selected">
<br />
</td>
<td class="tcs-selected">
<br />
</td>
<td class="tcs-selected">
<br />
</td>
<td class="tcs-selected">
<br />
</td>
<td class="tcs-selected">
<br />
</td>
</tr>
<tr>
<td class="tcs-selected">
Adjustable thermal trip<br />
Unadjustable electromagetic trip
</td>
<td class="tcs-selected">
<br />
</td>
<td class="tcs-selected">
<br />
</td>
<td class="tcs-selected">
.
</td>
<td class="tcs-selected">
.
</td>
<td class="tcs-selected">
<br />
</td>
<td class="tcs-selected">
<br />
</td>
</tr>
<tr>
<td class="tcs-selected">
Unadjustable
</td>
<td class="tcs-selected">
<br />
</td>
<td class="tcs-selected">
<br />
</td>
<td class="tcs-selected">
.
</td>
<td class="tcs-selected">
.
</td>
<td class="tcs-selected">
.
</td>
<td class="tcs-selected">
.
</td>
</tr>
<tr>
<td colspan="2" class="tcs-selected">
Machanical life
</td>
<td class="tcs-selected">
25000
</td>
<td class="tcs-selected">
25000
</td>
<td class="tcs-selected">
25000
</td>
<td class="tcs-selected">
20000
</td>
<td class="tcs-selected">
20000
</td>
<td class="tcs-selected">
20000
</td>
</tr>
<tr>
<td colspan="2" class="tcs-selected">
Electrical life
</td>
<td class="tcs-selected">
8000
</td>
<td class="tcs-selected">
8000
</td>
<td class="tcs-selected">
8000
</td>
<td class="tcs-selected">
7000
</td>
<td class="tcs-selected">
5000
</td>
<td class="tcs-selected">
5000
</td>
</tr>
<tr>
<td rowspan="3" class="tcs-selected">
<br />
</td>
<td class="tcs-selected">
L
</td>
<td class="tcs-selected">
78
</td>
<td class="tcs-selected">
90
</td>
<td class="tcs-selected">
105
</td>
<td class="tcs-selected">
140
</td>
<td class="tcs-selected">
210
</td>
<td class="tcs-selected">
210
</td>
</tr>
<tr>
<td class="tcs-selected">
D
</td>
<td class="tcs-selected">
70
</td>
<td class="tcs-selected">
70
</td>
<td class="tcs-selected">
103.5
</td>
<td class="tcs-selected">
103.5
</td>
<td class="tcs-selected">
103.5
</td>
<td class="tcs-selected">
103.5
</td>
</tr>
</tbody>
</table>
<br />
</p>
<p class="MsoNormal" style="text-align:justify;" align="justify">
<img src="http://i.bosscdn.com/product/b0/ee/73/936d916f4011e4e61105a06aed.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=9&t=80&text=a29ybGVuNjc2Ni5ib3NzZ29vLmNvbQ%3D%3D" title="MCCB With Overload Protection" alt="MCCB With Overload Protection" width="887" height="574" />
</p>
<p class="MsoNormal" align="justify">
<img src="http://i.bosscdn.com/product/0f/02/24/4e70b43ea0093aadcc628aa02b.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=9&t=80&text=a29ybGVuNjc2Ni5ib3NzZ29vLmNvbQ%3D%3D" title="MCCB With Overload Protection" alt="MCCB With Overload Protection" width="887" height="666" />
</p>
<p class="MsoNormal" align="justify">
<br />
</p>
<p class="MsoNormal" align="justify">
<img src="http://i.bosscdn.com/product/81/95/1a/e1243343e702dc5a4db846ae6c.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=9&t=80&text=a29ybGVuNjc2Ni5ib3NzZ29vLmNvbQ%3D%3D" title="MCCB With Overload Protection" alt="MCCB With Overload Protection" width="879" height="599" />
</p>
<p class="MsoNormal">
<br />
</p>
<p class="MsoNormal" style="text-align:justify;" align="justify">
<br />
<b></b>&nbsp;Production Capacity: we have more than 1500 workers and 100 expert engineers who can produce one container of our products in less than 5 days. Annual production is as follows; MCB 15 million poles, RCCB (thermal type) 2 million poles, (magnetic type) 800 thousand pole. Production of other products is also in the range of not less than thousands of poles annually.
</p>
<p class="MsoNormal" align="justify">
&nbsp;Pricing: we offer the best price to meet the requirement of all customers depending on the quality and the number of quantity demanded.
</p>
<p>
<br />
</p>
<p>
<br />
</p>korlenelectric.com

  More Products from this Supplier
 
Series Leakage Circuit Breakers For Building

Series Leakage Circuit Breakers For Building
High Quality Short Circuit Protector MCB 63A

High Quality Short Circuit Protector MCB 63A
10A 240V Over-Load Protector Circuit Breaker

10A 240V Over-Load Protector Circuit Breaker
High Breaking Mini Circuit Breakers

High Breaking Mini Circuit Breakers
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .