High Quality Residual Current Circuit Breaker 

  Category : Electronic and electrical->Electronic Parts->wiring equipments

     
High Quality Residual Current Circuit Breaker
       

  Product Specification
 
  Model No:      KNL1-63
  Country  CN
  Brand  Korlen
  Packing  carton
  Minimum Order  100
  Payment Term  L/C,T/T,D/P,Paypal,Money Gram,Western Union

 

    Product Detail
  <p class="MsoNormal">
Product advantages&nbsp;<br />
1.&nbsp;completely independent intellectual property right,national utility model patent.<br />
2.&nbsp;The overall is nice with sleek and smooth line.<br />
3.&nbsp;It is easy to distinguish with different colors of different specifications.<br />
4.&nbsp;&nbsp;It is comfortable to operate with embowed handles.<br />
5.&nbsp;&nbsp;It is flexible to install and dismantle with creative design clips.<br />
6.&nbsp;&nbsp;Setting oblate direction ,more beauty and more standard.<br />
7.&nbsp;&nbsp;To meet customers needs with more connection styles.<br />
8.&nbsp;Enhancing the ability of reflex arc when short circuit breaking with many improvements.<br />
9.&nbsp;&nbsp;Enhancing the ability of extinction arc when short- circuit breaking with many improvements.<br />
10.&nbsp;Short-circuit breaking capacity (ICS) of products get to 6KA combining many improvement.
</p>
<p>
When the&nbsp; products need store for a long time,not control the product store environment ,the metal and paint coat will be corroded.So take care: Products must store with room temperature and dry environment .Sealing when under high humidity environment.<br />
Don't store the products with acid volatile liquid and acid gas together.Don't store in high dust environment.<br />
Don't store the products in high temperature and humidity or lowest temperature for a long time ,please install and use as soon as possible.<br />
Don't contact the link wire before products used normally,preventing corrosion from pre-contacting.<br />
Please inform and operate under the manufacturer' advise referring to special store environment such as high temperature and humidity,islands near equator,ultra-low temperature area.
</p>
<p class="MsoNormal">
<table class="mce-item-table" cellspacing="1" cellpadding="0">
<tbody>
<tr class="firstRow">
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
Frame
</p>
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
63A
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
Rated working voltage
</p>
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
240/415V
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
Rated frequency
</p>
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
50/60Hz
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
Rated working current
</p>
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
16.20.25.32.40.50.63A
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
Rated residual operating current
</p>
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
0.03,0.1,0.3,0.5A
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
Rated residual un-operating current
</p>
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
0.015,0.05,0.15,0.25A
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
Sensibility
</p>
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
A Type.AC Type
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
Maximum operating time
</p>
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
I△n t≤0.1s , 5I△n t≤0.04
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
Rated making and breaking capacity
</p>
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
In≤50A 500A,In=63A 630A
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
Limiting value of un-operating current
</p>
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
6In
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
Rated limiting short-circuit current
</p>
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
3000A
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
Pole number
</p>
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
2.4P
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
Mechanical life
</p>
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
10000
</p>
</td>
</tr>
<tr>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
Electric life
</p>
</td>
<td class="mce-item-selected" style="border:1px solid #DDDDDD;">
<p>
4000
</p>
</td>
</tr>
</tbody>
</table>
<strong>Operation principle&nbsp;</strong><br />
<span style="font-family:arial;line-height:normal;">Each phase of conductor at the circuit breaker passes through the zero-sequence current transformer, and the secondary side of coil connects with the electromagnetic tripper. Under normal condition, the vector sum of each phase of current passing through zero-sequence current transformer is zero. The flux of the zero-sequence current transformer is zero. And the secondary output voltage is zero and the circuit breaker doesn`t zreo, and the zero-sequence current transformer would produce the magnetic flux, and the secondary side of coil would output the voltage. Once the leak current increases to drive the output voltage at the secondary side to grow to certain level, the electromagnetic release would activate to drive the operation mechanism to act to break the contact that connects the power, finally to realize the leak protection.</span>
</p>
<p class="MsoNormal">
<br />
</p>
<p class="MsoNormal">
<img src="http://i.bosscdn.com/product/e6/4c/a9/b56c38a45776c92232c35ff81a.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=9&t=80&text=a29ybGVuNjc2Ni5ib3NzZ29vLmNvbQ%3D%3D" title="Types Of ResidualCurrent Circuit Breaker" alt="Types Of ResidualCurrent Circuit Breaker" width="699" height="932" /><img src="http://i.bosscdn.com/product/ff/0e/35/e7ff3c43d23c02dd399235653b.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=9&t=80&text=a29ybGVuNjc2Ni5ib3NzZ29vLmNvbQ%3D%3D" title="Types Of ResidualCurrent Circuit Breaker" alt="Types Of ResidualCurrent Circuit Breaker" width="699" height="524" /><img src="http://i.bosscdn.com/product/a7/06/b9/a0be410c3bfe191e63bea1541a.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=9&t=80&text=a29ybGVuNjc2Ni5ib3NzZ29vLmNvbQ%3D%3D" title="Types Of ResidualCurrent Circuit Breaker" alt="Types Of ResidualCurrent Circuit Breaker" width="699" height="524" /><img src="http://i.bosscdn.com/product/36/a3/bd/cc96df14c39b139c439c582bd9.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=9&t=80&text=a29ybGVuNjc2Ni5ib3NzZ29vLmNvbQ%3D%3D" title="Types Of ResidualCurrent Circuit Breaker" alt="Types Of ResidualCurrent Circuit Breaker" width="699" height="932" /><img src="http://i.bosscdn.com/product/60/ab/8b/05f57c98bd3efc0774ff2c834c.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=22&p=9&t=80&text=a29ybGVuNjc2Ni5ib3NzZ29vLmNvbQ%3D%3D" title="Types Of ResidualCurrent Circuit Breaker" alt="Types Of ResidualCurrent Circuit Breaker" width="699" height="477" />
</p>
<p>
<br />
</p>
<p class="MsoNormal" style="text-align:justify;" align="justify">
&nbsp;Over company have more than 1500 workers and 100 expert engineers who can produce one container of our products in less than 5 days. Annual production is as follows; MCB 15 million poles, RCCB (thermal type) 2 million poles, (magnetic type) 800 thousand pole. Production of other products is also in the range of not less than thousands of poles annually.
</p>
<p>
<br />
</p>korlenelectric.com

  More Products from this Supplier
 
House Circuit Breakers Without Over-Current Protection

House Circuit Breakers Without Over-Current Protection
Micro Circuit Switch in Home 50HZ-60HZ Circuit Breakers

Micro Circuit Switch in Home 50HZ-60HZ Circuit Breakers
63A Mini Circuit Breaker 240V/415V Best Switch

63A Mini Circuit Breaker 240V/415V Best Switch
2P Low Voltage Earth Leakage Circuit Breaker RCCB

2P Low Voltage Earth Leakage Circuit Breaker RCCB
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .